#25701 - 04/20/04 04:17 PM
950 with ATI1505 remote on?
|
Deputy Gunslinger
Registered: 04/20/04
Posts: 4
Loc: San Diego, CA, USA
|
I was wondering if anyone else out there is running an ATI 1505 amplifier and has successfully gotten the 950 DC trigger to work with the ATI1505?
I know ATI is OEM for Outlaw Audio and the 1505 is probably very similar to the Outlaw 950 which is discontinued. The issue is that the ATI uses a DB25 connection for remote on (pin 11 & 23) and a high current relay. I don't know whether the 950's DC trigger (100mA) is sufficient and would really apreciate some feedback.
I just recieved my 950 last week and replaced my outdated Acurus ACT-3. My system has never sounded sweeter....
My System: Denon 2800 DVD Outlaw Audio 950 Pre/Pro ATI 1505 Amplifier Mitsubishi 55 HDTV PSB Status Silver i's (Mains) PSB Stratus C6 (Center) PSB Image 10 S (Surrounds) REL Acoustics Strata Sub
Thanks in advance!
Jason
|
Top
|
|
|
|
|
#25703 - 04/21/04 01:47 PM
Re: 950 with ATI1505 remote on?
|
Gunslinger
Registered: 06/17/01
Posts: 103
Loc: Fort Collins, CO USA
|
I too have the exact same combo of the 950 and the ATI 1505. I'd sure like to know the answer to this too!
Dan
_________________________
Down with the MPAA!! They are robbing you of your rights in the name of greed!
|
Top
|
|
|
|
|
#25705 - 04/21/04 05:30 PM
Re: 950 with ATI1505 remote on?
|
Deputy Gunslinger
Registered: 04/20/04
Posts: 4
Loc: San Diego, CA, USA
|
Originally posted by Dan Hitchman: I too have the exact same combo of the 950 and the ATI 1505. I'd sure like to know the answer to this too!
Dan Not a bad set up, eh? I will be testing it this weekend to see if I can get it to work. I will let you know the results.
|
Top
|
|
|
|
|
#25706 - 05/05/04 12:28 PM
Re: 950 with ATI1505 remote on?
|
Deputy Gunslinger
Registered: 04/20/04
Posts: 4
Loc: San Diego, CA, USA
|
Hi, I just wanted to foillow up and close this thread. There is no problems using the 950 remote on with the ATI1505, it works like a champ. Just as a note, the AMP must be in the standby position.
Regards, Jason
|
Top
|
|
|
|
|
#25707 - 05/13/04 04:51 PM
Re: 950 with ATI1505 remote on?
|
Gunslinger
Registered: 07/13/02
Posts: 34
Loc: San Jose, CA
|
I too have an ATI 1505 amp that I tried to run off the 950's 12 volt trigger. The main problem is the 950 trigger outputs only 100mA and the 1505 needs at least 350mA to engage the trigger. I currently use a remote controlled universal DC adaptor that I bought at Radio Shack to power the 1505 on and off. It is set to 12v @ 1000mA and works just fine. Not my preferred method but it beats doing it manually.
BTW, if anyone knows how to build an external circuit to amplify the output of the 950 trigger I'd be interested in trying it.
|
Top
|
|
|
|
|
#25708 - 05/27/04 02:50 AM
Re: 950 with ATI1505 remote on?
|
Gunslinger
Registered: 06/17/01
Posts: 103
Loc: Fort Collins, CO USA
|
That's great, but how did you wire the 950 and the ATI amp up for it to trigger the ON/OFF cycle?
Thanks!
Dan
_________________________
Down with the MPAA!! They are robbing you of your rights in the name of greed!
|
Top
|
|
|
|
|
#25709 - 05/27/04 08:33 AM
Re: 950 with ATI1505 remote on?
|
Gunslinger
Registered: 03/26/03
Posts: 47
Loc: Green Bay, WI USA
|
Reguarding the second paragraph of the first post in this thread, I was unaware that the Outlaw 950 has been discontinued. When did this happen? What replaces it? Thanks, Reed
|
Top
|
|
|
|
|
#25710 - 05/27/04 09:30 AM
Re: 950 with ATI1505 remote on?
|
Desperado
Registered: 03/21/01
Posts: 14054
Loc: Memphis, TN USA
|
He may be referring to the Outlaw 750 (their first product, a 5x165W amp), which was discontinued about two and a half years ago. The 950 is not discontinued. ------------------ gonk -- 950 Review | LFM-1 Review | Pre/Pro Comparison Chart | Saloon Links
|